Clearvu mesh combines close welded wire openings with dependable visibility across security boundaries. Its rigid steel construction discourages climbing and complicates attacks using basic hand tools. Boss Metal and Plastic Co., Ltd. manufactures welded mesh panels, posts, gates, and fittings in China. Our manufacturing experience supports projects across South Africa and other international markets.
Many buyers select clearvu mesh when solid boundary walls would obstruct surveillance. The narrow apertures help guards observe activity beyond the perimeter. The complete system also requires suitable posts, secure clamps, protective coatings, and properly designed foundations.
Clearvu mesh for perimeter security
Security planners need fences that deter entry without blocking important sightlines. Clearvu mesh provides a physical boundary while maintaining airflow and useful visibility. Warehouses, utilities, schools, and transport facilities can select different heights and wire configurations.
The designation 358 represents three inches, half an inch, and approximately eight-gauge wire. Metric descriptions commonly use 76.2 × 12.7 mm openings with roughly 4 mm wire. The drawing must define the mesh direction and centre-to-centre measurement.
The narrow spacing offers fewer useful fingerholds and footholds than wider meshes. It can delay intrusion attempts, but no fence guarantees absolute protection. Post foundations, gates, site monitoring, and security procedures still matter.
Clearvu mesh uses closely spaced welded wires to maintain visibility while reducing convenient climbing holds.
Clearvu mesh benefits for security sites
Each welded intersection helps distribute loads across the mesh. A suitable wire diameter supports cutting resistance and panel stiffness. Protective coatings reduce corrosion exposure, while secure fixings limit easy panel removal.
Anti-climb layout: small openings discourage convenient handholds and footholds.
Visible boundaries: open mesh supports guards, lighting, and CCTV observation.
Flexible design: select panel dimensions, posts, gates, and finishes.
Service planning: inspect welds, coatings, clamps, and foundations periodically.
For higher-risk installations, 358 Prison Mesh offers a related product configuration. Buyers can also consider an Anti Climb Security Fence system for controlled perimeters.
Visibility and surveillance
The open pattern helps security teams observe movement outside the boundary. Designers should test camera angles, floodlights, and gate locations together. Fences cannot eliminate blind spots created by buildings, vehicles, or landscaping.
A transparent perimeter can support detection systems without becoming their only protective layer. Installers should assess camera placement before confirming final post locations.
Clearvu mesh panel specifications
Our reference range includes 76.2 × 12.7 mm welded openings. Common panel widths include 2515, 2750, and 3000 mm for selected heights. Taller reference panels use 2200 or 2300 mm widths.
Material: low-carbon steel wire.
Mesh aperture: 76.2 × 12.7 mm.
Reference wire combinations: 3.0 × 4.0, 4.0 × 4.0, and 4.0 × 6.0 mm.
Panel heights: 2100, 2200, 2400, 2700, 3000, 3600, and 4000 mm.
Coatings: galvanised steel, galvanising plus powder coating, or other approved systems.
Common colours: RAL 6005 green and RAL 9005 black.
Packaging: protective film and export pallets.
These combinations represent different panel designs, not one universal 358 specification. Match each wire orientation and diameter to approved project drawings.
Mesh sizes and wire combinations
Standard 358 terminology usually describes approximately 4 mm wire with a 76.2 × 12.7 mm aperture. Alternative wire combinations can alter weight, stiffness, and cutting resistance. The 358 Anti-Climb Fence category illustrates a related product configuration.
Some projects use reinforced wires or wider apertures. Others choose 3D Fence Panels with V-shaped bends. Their bend geometry differs from flat welded panels. Customers should specify the structure instead of relying on the product name alone.
Clearvu mesh panel height and post schedule
The following table preserves seven reference configurations from the original product information. Confirm post lengths, fixing quantities, and actual bay spacing before production.
Clearvu mesh reference panel and installation schedule
Panel height (mm)
Panel width options (mm)
Wire combinations (mm)
Post length (mm)
Bracket quantity
2100
2515 / 2750 / 3000
3.0 × 4.0 / 4.0 × 4.0 / 4.0 × 6.0
2700
7
2200
2515 / 2750 / 3000
3.0 × 4.0 / 4.0 × 4.0 / 4.0 × 6.0
2800
8
2400
2515 / 2750 / 3000
3.0 × 4.0 / 4.0 × 4.0 / 4.0 × 6.0
3000
9
2700
2200 / 2300
3.0 × 4.0 / 4.0 × 4.0 / 4.0 × 6.0
3700
10
3000
2200 / 2300
3.0 × 4.0 / 4.0 × 4.0 / 4.0 × 6.0
4000
11
3600
2200 / 2300
3.0 × 4.0 / 4.0 × 4.0 / 4.0 × 6.0
4800
12
4000
2200 / 2300
3.0 × 4.0 / 4.0 × 4.0 / 4.0 × 6.0
5200
14
Bracket quantities refer to the original schedule and require project confirmation. Engineering calculations determine the final post section, footing, and fixing arrangement.
Reading the specification table
Panel width describes the product dimension, not necessarily the post centre distance. Connections, overlaps, and post profiles affect installation spacing. Site surveys should identify slopes, corners, drainage, and underground services.
Never select tall fencing solely from a generic table. Wind exposure, soil capacity, and potential impacts influence the foundation design. Local engineers should review critical installations.
Clearvu mesh wire strength and weld quality
Reliable welding connects vertical and horizontal steel wires at regular intersections. Production teams should monitor wire diameter, mesh pitch, panel squareness, and weld condition. Inspect samples for cracked welds, sharp burrs, and dimensional variation.
Consistent welding also helps panels retain their shape during coating and handling. However, welding quality alone cannot establish overall security performance. Material certificates and project testing may support higher-risk specifications.
Comparing 358 and alternative mesh
Close 358 openings offer more climbing resistance than many wide-aperture fences. Smaller wire diameters can reduce panel weight but also change rigidity. A Low Security Clear View Fencing configuration may suit lower-risk boundaries.
Another product family, ClearVu Fence Panels, includes multiple aperture and panel options. Security needs should guide those choices rather than appearance alone.
Clearvu mesh posts and installation hardware
Posts anchor the mesh and transfer loads into the ground. Choose square, rectangular, or formed steel sections according to engineering requirements. The Clearvu Fence Posts range includes relevant post options.
Flat bars, spider clips, bolts, and security nuts connect the panels to posts. The Clearvu Fence Clamps range covers compatible fastening components. Specify fixing counts for line posts, corners, and ends.
Post foundation and site setting-out
Begin with a boundary survey and approved installation drawings. Mark post centres before excavation or anchor drilling. Measure gate openings separately from standard fence bays.
Installers should maintain alignment while protecting finished coatings. Concrete foundations and base plates require suitable structural checks. Record any site changes before final acceptance.
Clearvu mesh galvanising and coatings
Metallic zinc coatings offer sacrificial protection against steel corrosion. Powder coatings supply colour and an additional environmental barrier. Buyers can specify hot-dip galvanising after fabrication or suitable precoated wire systems.
Powder Coated Clear View Fence combines coloured surfaces with an underlying protective system. Define coating thickness, preparation, and inspection standards before ordering.
Specify the treatment for posts, clamps, and gates alongside the panels. Mixed components can suffer uneven corrosion when protection levels differ.
Powder coating and colour selection
RAL 6005 green blends with many landscaped sites. RAL 9005 black offers a neutral architectural finish. Other RAL colours can match project branding and nearby buildings.
Colour choice does not determine protective performance by itself. Coating preparation, film thickness, and exposure matter more. Inspect finished panels for scratches, missed areas, and poor adhesion.
Clearvu mesh for coastal environments
Salt exposure increases corrosion risks near ports and coastlines. Projects should consider the entire coating system, including edges and fasteners. Additional maintenance may help preserve protective finishes.
For Clear View Fence South Africa projects, coastal and inland sites may need different specifications. Request documented coating properties rather than relying on a universal lifespan claim.
Production and quality inspection
Manufacturing begins with material selection, wire straightening, and cutting. Welding forms the mesh before any required bending. Surface preparation and protective treatment follow the approved production route.
Inspectors check wire sizes, apertures, welds, finished dimensions, and coating appearance. Packing checks help reduce damage during export. Buyers can arrange additional inspections according to the purchase agreement.
Clearvu mesh gates and security accessories
Entrance gates should match the adjoining fence height and visibility. A Clear View Fence Gate can accommodate pedestrian or vehicle access. Confirm hinges, locks, stops, and structural support independently.
The Clearvu Gates family includes compatible entrance options. Larger entrances may require Clearvu Sliding Gates with suitable travel space and safety controls.
Optional toppings require appropriate risk assessment and local compliance. Their attachment points must not weaken the original mesh or post system.
CCTV and perimeter monitoring
Position cameras near entrances, corners, and vulnerable boundary sections. Plan illumination for night visibility and minimise direct glare. Security staff should inspect alarm connections and access-control equipment regularly.
A mesh boundary helps observation but does not replace monitoring procedures. Combine physical protection with sensible detection and response planning.
Clearvu mesh packing and container loading
Panels need protective separators to prevent coating damage during transport. Steel pallets provide a sturdy base for bundling and container handling. Pack posts with caps and secure fittings in labelled cartons.
Before loading, verify piece counts and pallet stability. Record panel sizes, coating colours, and customer identification marks. Reinforce packages wherever handling equipment may contact exposed surfaces.
Shipment documentation
Commercial invoices should describe the actual fence components and agreed trade terms. Packing lists should identify panels, posts, gates, and accessory cartons. Container loading records can support delivery checks.
Buyers should confirm the destination port and unloading conditions. Accurate dimensions and weights help freight planning.
Clearvu mesh applications
Industrial warehouses use welded security mesh to define protected yards. Utilities and substations may need higher panels and controlled access. Airports, laboratories, and logistics facilities often require uninterrupted perimeter monitoring.
Clearvu Fence Panels also serve projects requiring modular replacement and matching gates. Residential estates can choose suitable heights where local rules permit.
Some projects select Clear Vu Fence systems for their visible mesh architecture. Other projects prioritise stronger sections, additional toppings, or specialised access points.
Routine maintenance
Inspect coatings, mesh joints, clamps, and post bases during scheduled maintenance. Remove debris that traps moisture against metal components. Repair coating damage using compatible materials.
Check gate movement and hardware wear more frequently in busy facilities. Keep records of inspections, repairs, and component replacements.
Clearvu mesh frequently asked questions
Does narrow mesh completely prevent climbing? No. It discourages useful footholds and handholds, but security depends on the complete installation.
Can buyers order customised panels? Yes. We can review drawings for alternative heights, widths, wire diameters, and fittings.
Which finish suits humid locations? Select a documented corrosion-protection system that matches site exposure. Review all metal components together.
Can the mesh support surveillance? Yes. Openings help visibility, while suitable cameras and lighting address other monitoring needs.
Do all products use 358 wire? No. Alternative wire combinations serve different structural and security requirements.
What to confirm before placing an order
Send the required perimeter length, panel height, mesh pitch, and wire orientation. Add post sizes, installation method, finish, colour, and delivery destination. Include gates, slopes, corners, and any additional security features.
BMP can review project drawings and prepare a corresponding export specification. Final production details depend on approved drawings and confirmed order requirements.
This clearvu mesh example illustrates a welded panel format suitable for coordinated posts, clamps, and gate designs.